Welcome to Iightstrade.com!

Mean well HVGC-100 100W Single Output Switching Power Supply

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union,Pay Pal

Departure Port : Shanghai Or Shenzhen

Product details

Supply Ability

  • Supply Ability: piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:23.4 cmWidth:6.8 cm
  • Height:3.88 cm
  • Packaging: piece

Product Specifications

Product Description

 

MODEL

HVGC-100-350

HVGC-100-700

 

RATED CURRENT

350mA

700mA

RATED POWER

99.75W

99.4W

RIPPLE & NOISE (max.)  Note.2

3Vp-p

1.5Vp-p

VOLTAGE ADJ.RANGE 

210 ~ 350mA

420 ~ 700mA

CURRENT ADJ.RANGE

Can be adjusted by internal potential meter or through output cable

SETUP, RISE TIME

4000ms, 3000ms at full load 440VAC / 347VAC ; B type 5000ms, 500ms at 95% load 440VAC / 347VAC

HOLD UP TIME (Typ.)

12ms at full load     440VAC / 347VAC

INPUT

VOLTAGE RANGE

200 ~ 480VAC 282VDC ~ 679VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF>= 0.95/440VAC PF >=0.98/347VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load

EFFICIENCY (Typ.)

92%

92%

AC CURRENT (Typ.)

0.32A / 347VAC          0.25A / 440VAC

INRUSH CURRENT (Typ.)

COLD START 75A / 440VAC

LEAKAGE CURRENT

<0.75mA / 440VAC

PROTECTION

OVERCURRENT NOTE.4

95 ~ 108%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

305 ~ 315V

152 ~ 160V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

100 10  (RTH2)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

SHORT CIRCUIT

Constant current limiting, recovers automatically after fault condition is removed

ENVIRO

NMENT

WORKING TEMP.

-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY &EMC

(Note 4)

SAFETY STANDARDS

UL8750, IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

HARMONIC CURRENT

Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A

OTHERS

MTBF

Khrs min.      MIL-HDBK-217F (25 )

DIMENSION

234*68*38.8mm (L*W*H)

PACKING 

Kg

NOTE

1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25 of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Derating may be needed under low input voltages. Please check the static characteristics for more details.

4. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.

5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the

complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.