MODEL

CEN-60-12

CEN-60-15

CEN-60-20

CEN-60-24

CEN-60-30

CEN-60-36

CEN-60-42

CEN-60-48

CEN-60-54

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

30V

36V

42V

48V

54V

CONSTANT CURRENT OPERATION VOLTAGE Note.5

9 ~ 12V

11.25 ~ 15V

15 ~ 20V

18 ~ 24V

22.5 ~ 30V

27 ~ 36V

31.5 ~ 42V

36 ~ 48V

40.5 ~ 54V

CURRENT RANGE

0 ~ 5A

0 ~ 4A

0 ~ 3A

0 ~ 2.5A

0 ~ 2A

0 ~ 1.7A

0 ~ 1.45A

0 ~ 1.3A

0 ~ 1.15A

RATED CURRENT

5A

4A

3A

2.5A

2A

1.7A

1.45A

1.3A

1.15A

RATED POWER

60W

60W

60W

60W

60W

61.2W

60.9W

62.4W

62.1W

RIPPLE & NOISE (max.)  Note.2

2Vp-p

2.4Vp-p

1.8Vp-p

2.4Vp-p

3Vp-p

3.6Vp-p

4Vp-p

4.6Vp-p

5Vp-p

VOLTAGE ADJ. RANGE

10.8~13.5V

13.5~ 17V

17 ~ 22V

22 ~ 27V

27 ~ 33V

33 ~ 40V

37 ~ 46V

43 ~ 53V

49 ~ 58V

VOLTAGE ADJ. RANGE

3.75 ~ 5A

3 ~ 4A

2.3 ~ 3A

1.9 ~ 2.5A

1.5 ~ 2A

1.3 ~ 1.7A

1.1~1.45A

1 ~ 1.3A

0.9~1.15A

VOLTAGE TOLERANCE   Note.3

10%

LINE REGULATION

3.0%

LOAD REGULATION

5.0%

SETUP, RISE TIME

1400ms / 230VAC 2800ms / 115VAC at full load

HOLD UP TIME (Typ.)

 

 

 

 

 

INPUT

VOLTAGE RANGE

Note.4 90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC PF>0.95 / 230VAC at full load

EFFICIENCY (Typ.)

86%

87%

88%

89%

90%

90%

90%

91%

91%

AC CURRENT (Typ.)

0.8A/115VAC 0.4A/230VAC

INRUSH CURRENT (Typ.)

45A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 110%     

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

14.5~ 17V

17.5~ 21V

22.8~ 26V

28 ~ 34V

34 ~ 38V

41 ~ 46V

47 ~ 52V

54 ~ 60V

59 ~ 65V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

85  10  (RTH1)

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL8750, TUV EN61347-1, EN61347-2-13, IP66 approved

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55015

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

523.4Khrs min. MIL-HDBK-217F (25 )

DIMENSION

183*62.5*40.5mm (L*W*H)

PACKING 

0.56Kg;24pcs/14.4Kg/1.11CUFT

 

 

 

 

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE >  10% and using additional drivers is highly recommended.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

 