Mean well PLN-30 30W Single Output LED Power Supply
Mean well CEN-60 60W Single Output LED Power Supply
MOQ : piece
Lead Time : Days
Seller Support : Trade Authenticity Guaranteed & Accepting
Payment : L/C,T/T,Western Union,Pay Pal
Departure Port : Shanghai Or Shenzhen
Product details
Supply Ability
- Supply Ability: piecesWarranty(Year):1 Year
Packaging & Delivery
- Length:18.3 cmWidth:6.25 cm
- Height:4.05 cm
- Packaging: piece
Product Specifications
Product Description
MODEL | CEN-60-12 | CEN-60-15 | CEN-60-20 | CEN-60-24 | CEN-60-30 | CEN-60-36 | CEN-60-42 | CEN-60-48 | CEN-60-54 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT OPERATION VOLTAGE Note.5 | 9 ~ 12V | 11.25 ~ 15V | 15 ~ 20V | 18 ~ 24V | 22.5 ~ 30V | 27 ~ 36V | 31.5 ~ 42V | 36 ~ 48V | 40.5 ~ 54V | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 4A | 0 ~ 3A | 0 ~ 2.5A | 0 ~ 2A | 0 ~ 1.7A | 0 ~ 1.45A | 0 ~ 1.3A | 0 ~ 1.15A | |
RATED CURRENT | 5A | 4A | 3A | 2.5A | 2A | 1.7A | 1.45A | 1.3A | 1.15A | |
RATED POWER | 60W | 60W | 60W | 60W | 60W | 61.2W | 60.9W | 62.4W | 62.1W | |
RIPPLE & NOISE (max.) Note.2 | 2Vp-p | 2.4Vp-p | 1.8Vp-p | 2.4Vp-p | 3Vp-p | 3.6Vp-p | 4Vp-p | 4.6Vp-p | 5Vp-p | |
VOLTAGE ADJ. RANGE | 10.8~13.5V | 13.5~ 17V | 17 ~ 22V | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | 37 ~ 46V | 43 ~ 53V | 49 ~ 58V | |
VOLTAGE ADJ. RANGE | 3.75 ~ 5A | 3 ~ 4A | 2.3 ~ 3A | 1.9 ~ 2.5A | 1.5 ~ 2A | 1.3 ~ 1.7A | 1.1~1.45A | 1 ~ 1.3A | 0.9~1.15A | |
VOLTAGE TOLERANCE Note.3 | 10% | |||||||||
LINE REGULATION | 3.0% | |||||||||
LOAD REGULATION | 5.0% | |||||||||
SETUP, RISE TIME | 1400ms / 230VAC 2800ms / 115VAC at full load | |||||||||
HOLD UP TIME (Typ.) |
| |||||||||
INPUT | VOLTAGE RANGE | Note.4 90 ~ 295VAC 127 ~ 417VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR | PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC PF>0.95 / 230VAC at full load | |||||||||
EFFICIENCY (Typ.) | 86% | 87% | 88% | 89% | 90% | 90% | 90% | 91% | 91% | |
AC CURRENT (Typ.) | 0.8A/115VAC 0.4A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | 45A/230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||||
PROTECTION | OVER CURRENT | 95 ~ 110% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 14.5~ 17V | 17.5~ 21V | 22.8~ 26V | 28 ~ 34V | 34 ~ 38V | 41 ~ 46V | 47 ~ 52V | 54 ~ 60V | 59 ~ 65V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | 85 10 (RTH1) | |||||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70 (Refer to output load derating curve) | ||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80 , 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50 ) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | UL8750, TUV EN61347-1, EN61347-2-13, IP66 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25 / 70% RH | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55015 | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A | |||||||||
OTHERS | MTBF | 523.4Khrs min. MIL-HDBK-217F (25 ) | ||||||||
DIMENSION | 183*62.5*40.5mm (L*W*H) | |||||||||
PACKING | 0.56Kg;24pcs/14.4Kg/1.11CUFT | |||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. |
You May Like
- Free Member
- Trade Assurance
Business Type : Trading Company,Exporter,Agent
Company Location:
Year Established: 22YRS
You May Like
-
Mean well PLN-30 30W Single Output LED Power Supply
-
Mean well LDD-H DC-DC Constant Current LED driver
-
Mean well HVG-100 100W Single Output Switching Power Supply
-
Mean well PLC-60 60W Single Output LED Power Supply
-
Mean well APV-12 12W Single Output Switching Power Supply
-
Mean well CEN-60 60W Single Output LED Power Supply
-
Mean well PLN-45 45W Single Output LED Power Supply
-
Mean well ELN-60 60W Single Output Class 2 Switching Power Supply /d
-
Mean well PCD-25 25W Single Output AC Dimmable LED Power Supply
-
Mean well PLC-45 45W Single Output LED Power Supply