Welcome to Iightstrade.com!

Mean well PLN-45 45W Single Output LED Power Supply

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union,Pay Pal

Departure Port : Shanghai Or Shenzhen

Product details

Supply Ability

  • Supply Ability: piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:18.1 cmWidth:6.15 cm
  • Height:3.5 cm
  • Packaging: piece

Product Specifications

Product Description

 

MODEL

PLN-45-12                

PLN-45-15

PLN-45-20

PLN-45-24

PLN-45-27

PLN-45-36

PLN-45-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

27V

36V

48V

CONSTANT CURRENT OPERATION VOLTAGE Note.5

9 ~ 12V           

11.25 ~15V

  15 ~ 20V    

18 ~24V

20.25 ~27V

27 ~ 36V

  36 ~ 48V

CURRENT RANGE

0 ~ 3.8A               

0 ~ 3A   

0 ~ 2.3A 

0 ~ 1.9A 

0 ~ 1.7A 

0 ~ 1.25A

0 ~ 0.95A

RATED CURRENT

3.8A

3A

2.3A

1.9A

1.7A

1.25A

0.95A

RATED POWER

45.6W

45W

46W

45.6W

45.9W

45W

45.6W

RIPPLE & NOISE (max.)  Note.2

2Vp-p                 

2.4Vp-p 

1.8Vp-p 

2.7Vp-p

2.7Vp-p

3.6Vp-p

4.6Vp-p

VOLTAGE ADJ. RANGE Note.5

11.5 ~ 13V        

14.5 ~ 16.2V

19.5 ~ 22V

24 ~ 26V

25 ~ 30V

32.5 ~ 39V

43.6 ~ 51.8V

Can be adjusted by internal potential meter SVR1

CURRENT ADJ.RANGE Note.5

3% ~ -25%. Can be adjusted by internal potential meter SVR2

VOLTAGE TOLERANCE   Note.3

10%

LINE REGULATION

3.0%

LOAD REGULATION

5.0%

SETUP, RISE TIME

1500ms / 230VAC 3000ms / 115VAC at full load

HOLD UP TIME (Typ.)

 

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC

EFFICIENCY (Typ.)

83.5%

85%

86.5%

86.5%

86.5%

87.5%

87.5%

AC CURRENT (Typ.)

0.55A/115VAC 0.25A/230VAC

INRUSH CURRENT (Typ.)

40A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 110%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed.

OVER VOLTAGE

13.8 ~ 16V          

17.5 ~ 21V

22.8 ~ 25V  

28 ~ 32V

31 ~ 35V 

41 ~ 46V 

54 ~ 60V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

95  10  (TSW1) detect on heatsink of power transistor

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +50 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL879, UL8750, UL1310 Class 2, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms/500VDC / 25 / 70%RH

EMI CONDUCTION & RADIATION

Compliance to EN55015

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; En61547, light industry level,  criteria A

 

OTHERS

MTBF

497.8Khrs min. MIL-HDBK-217F (25 )

DIMENSION

181*61.5*35mm (L*W*H)

PACKING 

0.5Kg; 24pcs/13Kg/0.75CUFT

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

Direct connecting to LEDs is not suggested for models with ?RIPPLE & NOISE?  >  10% and using additional drivers is highly recommended.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.

6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

 

You May Like