MODEL | ELN-60-9 | ELN-60-12 | ELN-60-15 | ELN-60-24 | ELN-60-27 | ELN-60-48 | |
OUTPUT | DC VOLTAGE | 9V | 12V | 15V | 24V | 27V | 48V |
CONSTANT CURRENT OPERATION VOLTAGE Note.5 | 8 3 ~ 9V | 6 ~ 12V | 7.5 ~ 15V | 12 ~ 24V | 13.5 ~ 27V | 24 ~ 48V | |
CURRENT RANGE | 0 ~ 5A | 0 ~ 5A | 0 ~ 4A | 0 ~ 2.5A | 0 ~ 2.3A | 0 ~ 1.3A | |
RATED CURRENT | 5A | 5A | 4A | 2.5A | 2.3A | 1.3A | |
RATED POWER | 45W | 60W | 60W | 60W | 62.1W | 62.5W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | 8.7 ~ 10.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V | 24.3 ~ 29.7V | 43.2 ~ 52.8V | |
Can be adjusted by internal potential meter SVR1 | |||||||
VOLTAGE ADJ. RANGE | -25% ~ 3%. Can be adjusted by internal potential meter SVR2 | ||||||
VOLTAGE TOLERANCE Note.3 | 5.0% | ||||||
LINE REGULATION | 1.0% | ||||||
LOAD REGULATION | 2.0% | ||||||
SETUP, RISE TIME | 500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR |
| ||||||
EFFICIENCY (Typ.) | 82% | 85% | 86% | 87% | 87% | 88% | |
AC CURRENT (Typ.) | 1.2A/115VAC 0.7A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 60A/230VAC | ||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | ||||||
PROTECTION | OVER CURRENT | 95 ~ 110% | |||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 11 ~ 13.5V | 13.8 ~ 16V | 17.5 ~ 21V | 28 ~ 32V | 31 ~ 35V | 54 ~ 60V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
FUNCTION DIMMING CONTROL | 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz | ||||||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60 (Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80 , 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50 ) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1, EN61347-2-13 | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2 Class A, EN61000-3-3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A | ||||||
OTHERS | MTBF | 603Khrs min. MIL-HDBK-217F (25 ) | |||||
DIMENSION | 181*61.5*35mm (L*W*H) | ||||||
PACKING | 0.4Kg; 24pcs/11Kg/0.75CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB. 8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications. 9. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of |
You May Like
- Free Member
- Trade Assurance
Business Type : Trading Company,Exporter,Agent
Company Location:
Year Established: 23YRS
You May Like
-
Mean well PLN-30 30W Single Output LED Power Supply
-
Mean well LDD-H DC-DC Constant Current LED driver
-
Mean well HVG-100 100W Single Output Switching Power Supply
-
Mean well PLC-60 60W Single Output LED Power Supply
-
Mean well APV-12 12W Single Output Switching Power Supply
-
Mean well CEN-60 60W Single Output LED Power Supply
-
Mean well PLN-45 45W Single Output LED Power Supply
-
Mean well ELN-60 60W Single Output Class 2 Switching Power Supply /d
-
Mean well PCD-25 25W Single Output AC Dimmable LED Power Supply
-
Mean well PLC-45 45W Single Output LED Power Supply