Product Description

 

MODEL

ELN-60-9

ELN-60-12

ELN-60-15 

ELN-60-24

ELN-60-27

ELN-60-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

9V

12V

15V

24V

27V

48V

CONSTANT CURRENT OPERATION VOLTAGE Note.5

8 3 ~ 9V

6 ~ 12V

7.5 ~ 15V

12 ~ 24V

13.5 ~ 27V

24 ~ 48V

CURRENT RANGE

0 ~ 5A  

0 ~ 5A 

0 ~ 4A

0 ~ 2.5A

0 ~ 2.3A

0 ~ 1.3A

RATED CURRENT

5A

5A

4A

2.5A

2.3A

1.3A

RATED POWER

45W

60W

60W

60W

62.1W

62.5W

RIPPLE & NOISE (max.)  Note.2

120mVp-p

120mVp-p

150mVp-p

150mVp-p

200mVp-p

250mVp-p

VOLTAGE ADJ. RANGE

8.7 ~ 10.5V

10.8 ~ 13.2V

13.5 ~ 16.5V

21.6 ~ 26.4V

24.3 ~ 29.7V

43.2 ~ 52.8V

Can be adjusted by internal potential meter SVR1

VOLTAGE ADJ. RANGE

-25% ~ 3%. Can be adjusted by internal potential meter SVR2

VOLTAGE TOLERANCE   Note.3

5.0%

LINE REGULATION

1.0%

LOAD REGULATION

2.0%

SETUP, RISE TIME

500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC  16ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

 

EFFICIENCY (Typ.)

82%

85%

86%

87%

87%

88%

AC CURRENT (Typ.)

1.2A/115VAC 0.7A/230VAC

INRUSH CURRENT (Typ.)

COLD START 60A/230VAC

LEAKAGE CURRENT

0.25mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 110%     

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

11 ~ 13.5V

13.8 ~ 16V

17.5 ~ 21V

28 ~ 32V

31 ~ 35V

54 ~ 60V

Protection type : Shut down o/p voltage, re-power on to recover

FUNCTION DIMMING CONTROL

1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz

 

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +60 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1, EN61347-2-13

WITHSTAND VOLTAGE 

I/P-O/P:3KVAC

ISOLATION RESISTANCE

I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class A, EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A

 

OTHERS

MTBF

603Khrs min. MIL-HDBK-217F (25 )

DIMENSION

181*61.5*35mm (L*W*H)

PACKING 

0.4Kg; 24pcs/11Kg/0.75CUFT

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.

8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.

9. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of