Product Description

 

MODEL

ULP-150-12 

ULP-150-15

ULP-150-24

ULP-150-36

ULP-150-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

24V

36V

48V

CURRENT RANGE

0 ~ 12.5A

0 ~ 10A

0 ~ 6.3A

0 ~ 4.2A

0 ~ 3.2A

RATED CURRENT

12.5A

10A

6.3A

4.2A

3.2A

RATED POWER

150W

150W

151.2W

151.2W

153.6W

RIPPLE & NOISE (max.)  Note.2

100mVp-p

150mVp-p

150mVp-p

250mVp-p

250mVp-p

VOLTAGE ADJ. RANGE

11.0~13.2V

13.5~16.5V

21.6~26.4V

32.4~39.6V

43.2~52.8V

VOLTAGE TOLERANCE   Note.3

2.0%

2.0%

2.0%

2.0%

2.0%

LINE REGULATION

0.5%

0.5%

0.5%

0.5%

0.5%

LOAD REGULATION

1.0%

1.0%

1.0%

1.0%

1.0%

SETUP, RISE TIME

2000ms, 100ms/230VAC  3000ms, 100ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC   16ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF  0.96/230VAC  PF   0.98/115VAC PF  0.94/277VAC at full load; PF 0.9/230VAC at 50%~100% load

EFFICIENCY (Typ.)

91.5%

91.5%

93%

93%

93%

AC CURRENT (Typ.)

2A/115VAC   1A/230VAC

INRUSH CURRENT (Typ.)

Cold start 65A/230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

 

PROTECTION

OVER LOAD

145~185% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

SHORT CIRCUIT

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

13.6 ~ 16.3V

17 ~ 21V

26.7 ~ 32.4V

41.4 ~ 48.6V

53 ~ 64.8V

Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery

OVER TEMPERATURE

95  5  (RTH2)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 60

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

EN61347-1,EN61347-2-13,IEC61347-1,IEC61347-2-13,UL8750 approved

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH

EMI CONDUCTION & RADIATION

Compliance to EN55015,EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2,CLASS C( 60% load),EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

216.3K hrs min. MIL-HDBK-217F (25 )

DIMENSION

215*67.4*33mm (L*W*H)

PACKING 

0.67kg;  24PCS/17.5kg/0.65CUFT

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the static characteristics for more details.

5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets

EMC directives.

 

You May Like