Welcome to Iightstrade.com!

Mean well CLG-100 100W Single Output Switching Power Supply

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union,Pay Pal

Departure Port : Shanghai Or Shenzhen

Product details

Supply Ability

  • Supply Ability: piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:22.22 cmWidth:6.8 cm
  • Height:3.88 cm
  • Packaging: piece

Product Specifications

Product Description

 

MODEL

CLG-100-12

CLG-100-15

CLG-100-20

CLG-100-24

CLG-100-27

CLG-100-36

CLG-100-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

27V

36V

48V

CONSTANT CURRENT OPERATION VOLTAGE Note7

9 ~ 12V

11.25 ~ 15V

15 ~ 20V

18 ~ 24V

20.25 ~ 27V

27 ~ 36V

36 ~ 48V

RATED CURRENT

5A

5A

4.8A

4A

3.55A

2.65A

2A

RATED POWER

60W

75W

96W

96W

95.85W

95.4W

96W

RIPPLE & NOISE (max.)  Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

Fixed. Can be modified between 0% ~ -15% rated output voltage

CURRENT ADJ. RANGE

Fixed. Can be modified between 3% ~ -25% rated output current

VOLTAGE TOLERANCE   Note.3

3.0%

3.0%

3.0%

3.0%

3.0%

2.0%

2.0%

LINE REGULATION

1.0%

LOAD REGULATION

2.0%

SETUP, RISE TIME

1200ms, 80ms / 230VAC 1200ms, 80ms / 115VAC at full load

HOLD UP TIME (Typ.)

60ms / 230VAC 30ms / 115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF>0.95/230VAC PF>0.95/115VAC at full load PF 0.9 at 75 ~ 100%  load

EFFICIENCY (Typ.)

84.5%

86.5%

90%

90%

90%

90%

89%

AC CURRENT (Typ.)

12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC

INRUSH CURRENT (Typ.)

COLD START 40A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 102%    

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

13 ~ 16V

16.5 ~ 20V

22 ~ 27V

27 ~ 34V

30 ~ 36V

39 ~ 48V

52 ~ 64V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

90  10  (RTH2)

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent

CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55015, EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

301Khrs min. MIL-HDBK-217F (25 )

DIMENSION

222.2*68*38.8mm (L*W*H)

PACKING 

1.0Kg; 12pcs/13Kg/0.49CUFT

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the static characteristics for more details.

5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement

of UL1310 class 2.

6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68    .

7. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.

9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

 

               

 

You May Like