Product Description

 

MODEL

   CLG-60-12

CLG-60-15

CLG-60-20

CLG-60-24

CLG-60-27

CLG-60-36

CLG-60-48

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

27V

36V

48V

CONSTANT CURRENT OPERATION VOLTAGE Note7

8.4 ~ 12V

10.5 ~ 15V

14 ~ 20V

16.8 ~ 24V

18.9 ~ 27V

25.2 ~ 36V

33.6 ~ 48V

RATED CURRENT

5A

4A

3A

2.5A

2.3A

1.7A

1.3A

CURRENT RANGE

0 ~ 5A 

0 ~ 4A

0 ~ 3A

0 ~ 2.5A

0 ~ 2.3A

0 ~ 1.7A

0 ~ 1.3A

RATED POWER

60W

60W

60W

60W

62.1W

61W

62.5W

RIPPLE & NOISE (max.)  Note.2

2Vp-p

2.4Vp-p

1.8Vp-p

2.7Vp-p

2.7Vp-p

3.6Vp-p

4.6Vp-p

VOLTAGE ADJ. RANGE

11.5 ~ 13V

14.5 ~ 16.2V

19.5 ~ 22V

24 ~ 26V

25 ~ 30V

32.5 ~ 39V

43.6 ~ 51.8V

Fixed can be modified between the range above

CURRENT ADJ. RANGE

Fixed. Can be modified between 3% ~ -25% rated output voltage

VOLTAGE TOLERANCE   Note.3

10%

LINE REGULATION

3.0%

LOAD REGULATION

5.0%

SETUP TIME

3000ms / 230VAC 5000ms / 115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF  0.9 at 75 ~ 100% load, 115VAC / 230VAC

EFFICIENCY (Typ.)

85%

86%

87.5%

87%

88%

89%

89%

AC CURRENT (Typ.)

0.8A/115VAC 0.4A/230VAC

INRUSH CURRENT (Typ.)

40A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 110%

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

13.8 ~ 16V

17.5 ~ 21V

22.8 ~ 25V

28 ~ 32V

31 ~ 35V

41 ~ 46V

54 ~ 60V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

12V: 90 10  (TSW1) detect on heatsink of power transistor

15V ~ 48V: 85 10 (TSW1) detect on heatsink of power transistor

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V) ;

J61347-1, J61347-2-13(20~27only), IP67 approved

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55015, EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

495.7Khrs min. MIL-HDBK-217F (25 )

DIMENSION

195.6*61.5*38.8mm (L*W*H)

PACKING 

0.86Kg; 16pcs/14.8Kg/0.54CUFT

 

 

 

 

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE  >  10% and using additional drivers is highly recommended.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltage. Please check the static characteristics for more details.

5. Constant current operation region is within 65% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

 