Welcome to Iightstrade.com!

Mean well HLG-100H 100W Single Output Switching Power Supply

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union,Pay Pal

Departure Port : Shanghai Or Shenzhen

Product details

Supply Ability

  • Supply Ability: piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:22.0 cmWidth:6.8 cm
  • Height:3.88 cm
  • Packaging: piece

Product Specifications

Product Description

 

MODEL

HLG-100H-20 □

HLG-100H-24□

HLG-100H-30□

HLG-100H-36□

HLG-100H-42□

HLG-100H-48□

HLG-100H-54□

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

20V

24V

30V

36V

42V

48V

54V

CONSTANT CURRENT REGION Note.4

10 ~ 20V

12 ~ 24V

15 ~ 30V

18 ~ 36V

21 ~ 42V  

24 ~ 48V   

27 ~ 54V

CURRENT RANGE

 

 

 

 

 

 

 

RATED CURRENT

4.8A

4A

3.2A

2.65A

2.28A

2A

1.77A

RATED POWER

96W

96W

96W

95.4W

95.76W

96W

95.58W

RIPPLE & NOISE (max.)

150mVp-p

150mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE NOTE.6

17 ~ 22V  

22 ~ 27V      

27 ~ 33V

33 ~ 40V

38 ~ 46V 

43 ~ 53V

49 ~ 58V

CURRENT ADJ. RANGE

Can be adjusted by internal potential meter or through output cable

3 ~ 4.8A   

2.5 ~ 4A   

2 ~ 3.2A  

1.65 ~ 2.65A

1.4 ~ 2.28A

1.25 ~ 2A

1.1 ~ 1.77A

VOLTAGE TOLERANCE   Note.3

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

1.0%

LINE REGULATION

0.5%

LOAD REGULATION

0.5%

SETUP, RISE TIME NOTE.8

2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC

HOLD UP TIME (Typ.)

16ms at full load 230VAC /115VAC

 

 

 

 

INPUT

VOLTAGE RANGE NOTE.5

90 ~ 305VAC 127 ~ 431VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF  0.95/230VAC PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100%  load

EFFICIENCY (Typ.)

93%

93%

93%

93%

93%

93%

93%

AC CURRENT (Typ.)

1.2A / 115VAC 0.55A / 230VAC 0.5A / 277VAC

INRUSH CURRENT (Typ.)

COLD START 75A/230VAC

LEAKAGE CURRENT

<0.75mA / 277VAC

 

PROTECTION

OVER CURRENT

95 ~ 106%    

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

23 ~ 27V            

28 ~ 34V 

34 ~ 38V

41 ~ 46V 

47 ~ 53V 

54 ~ 60V

59 ~ 65V

Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery

OVER TEMPERATURE

100  10  (RTH2)

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

 

 

 

ENVIRONMENT

WORKING TEMP.

-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS NOTE.7

UL879, UL8750, UL1310 Class 2, TUV EN60950-1, EN61347-1, EN61347-2-13 independent

EN61347-1, EN61347-2-13 independent IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55015, EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 60% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A

 

OTHERS

MTBF

192.2Khrs min. MIL-HDBK-217F (25 )

DIMENSION

220*68*38.8mm (L*W*H)

PACKING 

1.12Kg; 12pcs/14.4Kg/0.76CUFT

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Constant current operation region is within 62.5% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

5. Derating may be needed under low input voltages. Please check the static characteristics for more details.

6. Type A only.

7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.

8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.

9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

10. Refer to warranty statement.

 

You May Like