Welcome to Iightstrade.com!

Mean well CLG-150 150W Single Output Switching Power Supply

MOQ : piece

Lead Time : Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union,Pay Pal

Departure Port : Shanghai Or Shenzhen

Product details

Supply Ability

  • Supply Ability: piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:22.22 cmWidth:6.8 cm
  • Height:3.88 cm
  • Packaging: piece

Product Specifications

Product Description

 

MODEL

CLG-150-12□

CLG-150-15□

CLG-150-20□

CLG-150-24□

CLG-150-30□

CLG-150-36□

CLG-150-48□

 

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

15V

20V

24V

30V

36V

48V

CONSTANT CURRENT OPERATION VOLTAGE Note.5

9 ~12V

11.25 ~ 15V

15 ~ 20V

18 ~ 24V

22.5 ~ 30V

27 ~ 36V

36 ~ 48V

RATED CURRENT

11A

9.5A

7.5A

6.3A

5A

4.2A

3.2A

RATED POWER

132W

142.5W

150W

151.2W

150W

151.2W

153.6W

RIPPLE & NOISE (max.)  Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

9 ~ 13V

13 ~ 17V

17 ~ 22V

22 ~ 27V

26 ~ 32V

31 ~ 41V

40 ~ 56V

CURRENT ADJ. RANGE

Can be adjusted by internal potential meter or through output cable

   5.5 ~ 11A

4.75 ~ 9.5A

3.75 ~ 7.5A

3.15 ~ 6.3A

2.5 ~ 5A

2.1 ~ 4.2A

1.6 ~ 3.2A

VOLTAGE TOLERANCE   Note.3

2.0%

2.0%

2.0%

1.0%

1.0%

1.0%

1.0%

LINE REGULATION

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

0.5%

LOAD REGULATION

1.0%

1.0%

1.0%

0.5%

0.5%

0.5%

0.5%

SETUP, RISE TIME

3000ms, 80ms at full load 230VAC /115VAC

HOLD UP TIME (Typ.)

50ms / 230VAC 16ms / 115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE

90 ~ 295VAC 127 ~ 417VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR

PF 0.95/230VAC  PF 0.98/115VAC at full load and rated output voltage PF 0.9 at 75 ~ 100% load

EFFICIENCY (Typ.)

88%

88%

90%

90%

91%

91%

91%

AC CURRENT (Typ.)

2A / 115VAC 1A / 230VAC

INRUSH CURRENT (Typ.)

COLD START 65A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

 

PROTECTION

OVER CURRENT

95 ~ 108%    

Protection type : Constant current limiting, recovers automatically after fault condition is removed

SHORT CIRCUIT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

13.5 ~ 16V

18 ~ 20V

23 ~ 27V

28 ~ 34V 

33 ~ 36V

42 ~ 48V

57 ~ 65V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

100   10 (RTH2)

Protection type : Shut down o/p voltage, re-power on to recover

 

 

 

ENVIRONMENT

WORKING TEMP.

-30 ~ +70 (Refer to output load derating curve)

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +80 , 10 ~ 95% RH

TEMP. COEFFICIENT

0.03%/ (0 ~ 50 )

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes

 

 

 

 

 

SAFETY &EMC(Note 4)

SAFETY STANDARDS

UL1012 ; EN61347-1, EN61347-2-13 independent (except for CLG-150 C type) ; UL60950-1, TUV EN60950-1 ; J61347-1,

WITHSTAND VOLTAGE 

I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25 / 70% RH

EMI CONDUCTION & RADIATION

Compliance to EN55015, EN55022 (CISPR22) Class B

HARMONIC CURRENT

Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3

EMS

IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV),  criteria A

 

OTHERS

MTBF

303.7Khrs min. MIL-HDBK-217F (25 )

DIMENSION

222.2*68*38.8mm (L*W*H)(CLG-150-Blank/A/B) 229*68*38.8mm (L*W*H)(CLG-150-C)

PACKING 

1.0Kg; 12pcs/13Kg/0.49CUFT(CLG-150-Blank/A/B) 1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C)

 

 

 

 

 

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.

5. Derating may be needed under low input voltages. Please check the static characteristics for more details.

6. Type A and type C only.

7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.

8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

More LED Products